Delta crusader

Delta crusader

bladder was leaking
- remove 2 small set-screws
- thread a 1/2-13 bolt into the end cap to press it out
- pull the bladder assembly out (twisting back and forth seems to help as it is not threaded)
*** ALUMINUM COMPONENTS; CAREFUL NOT TO COLLAPSE WHEN CLAMPING ***
- disassemble, replace bladder and re-assemble
*** there are two bladders and one bladder assembly in the Crusader asset tote ***
    • Related Articles

    • 21017- delta laser-Temp Fault

      High temp fault on chiller Reset pressure switch inside of chiller
    • 21057-Viper Axis 7 not homing

      Axis 7 was set as the machine post master, Even tho post master was not enabled it was blocking the homing signal. setting post master to 0 fixed the issue. Delta is going to change the code so it shouldn't happen again.
    • 20938- Indigo-All Errors

      Various errors showing, "air pressure" error is first in list. Most of the time this is caused by a missing element in to OPC menu. Find video titled Indigo OCP fix in location: W:\Engineering\Equipment Downloaded Manuals and Information\Indigo ...